煙氣分析儀
產(chǎn) 品 說 明
船用 testo350煙氣分析儀
根據(jù)MARPOL Annex VI和NOx Techinial Code(2008)獲得挪威DNV船級(jí)社,德國勞氏GL船級(jí)社,日本NK海事協(xié)會(huì)認(rèn)證
預(yù)標(biāo)定氣體傳感器可在現(xiàn)場更換,可以不會(huì)因?yàn)榭捎眯远幌拗?/span>
準(zhǔn)備測試在2分鐘內(nèi)完成
測試過的氣體傳感器,與參考的測量技術(shù)一致
Testo隆重推出,用于檢查船用柴油發(fā)動(dòng)機(jī)廢氣:船用testo 350 MARITIME煙氣分析儀!
煙氣分析儀根據(jù)MARPOL附則VI和NOx技術(shù)規(guī)范2008測量柴油船發(fā)動(dòng)機(jī)的排放。
技術(shù)參數(shù) | |
---|---|
重量 |
Approx. 17 kg |
尺寸 |
565 x 455 x 265 mm (case) |
操作溫度 |
5 ~ +45 °C |
外殼 |
ABS / ABS-PC 玻璃纖維 10% |
可連接的探頭 |
1 x combustion air temperature probe; 1 x flue gas probe; 1 x temperature probe; 1 x temperature probe; 1 x differential pressure |
Product colour |
Black |
標(biāo)準(zhǔn) |
Germanischer Lloyd (DNV GL) Certificate Nippon Kaijik Kyokai (Class NK) certificate according to MARPOL Annex VI and NOx Technical Code 2008 |
電源 |
Li ion rechargeable battery; AC mains unit 100 V to 240 V (50 to 60 Hz) |
耗電量 |
max. 40 W |
泵流量 |
1 l / min. with flow monitoring |
最大煙氣正壓 |
50 mbar |
最大煙氣負(fù)壓 |
-300 mbar |
露點(diǎn)計(jì)算 |
0.04 °Ctd; 99 °Ctd |
數(shù)據(jù)傳輸 |
IR/IRDA界面; Bluetooth®; USB 接口; data bus; trigger input; 差壓; probe input/ probe inputs; DC-voltage input; Mains connection; dilution gas inlet for measurement range extension |
存放溫度 |
-20 ~ +50 °C |
Type K (NiCr-Ni) | |
---|---|
測量范圍 |
-200 ~ +1370 °C |
測量精度 |
±0.4 °C (-100 ~ +200.0 °C) ±1.0 °C (-200 ~ -+1001.0 °C) ±1.0 °C (200 ~ +1370.0 °C) |
分辨率 |
±0.1 °C (-200 ~ +1370.0 °C) |
絕壓 | |
---|---|
測量范圍 |
600 ~ 1150 hPa |
測量精度 |
10.0 ±10 hPa at -5 ~ 45 °C |
O?測量 | |
---|---|
測量范圍 |
0 ~ 25 Vol.% |
測量精度 |
According to to MARPOL Annex VI and NOx Technical Code |
CO (H?補(bǔ)償) | |
---|---|
測量范圍 |
0 ~ 3000 ppm |
測量精度 |
According to to MARPOL Annex VI and NOx Technical Code |
NO測量 | |
---|---|
測量范圍 |
0 ~ 3000 ppm |
測量精度 |
According to to MARPOL Annex VI and NOx Technical Code |
NO?測量 | |
---|---|
測量范圍 |
0 ~ 500 ppm |
測量精度 |
According to to MARPOL Annex VI and NOx Technical Code |
SO?測量 | |
---|---|
測量范圍 |
0 ~ 3000 ppm |
測量精度 |
According to to MARPOL Annex VI and NOx Technical Code |
CO?測量(紅外) | |
---|---|
測量范圍 |
0 ~ 40 Vol.% |
測量精度 |
According to to MARPOL Annex VI and NOx Technical Code |